These automatic transfer switches are designed for a variety of standby power applications. They provide flexibility, reliability, and value in a compact package. The open and delayed transition contactor-based ATS provides fully functioning tr... Read More
Overview
200A Automatic Transfer Switch (ATC3C2X20200WSU)
These automatic transfer switches are designed for a variety of standby power applications. They provide flexibility, reliability, and value in a compact package. The open and delayed transition contactor-based ATS provides fully functioning transfer in applications where a momentary loss of power is acceptable during transfer and retransfers between normal and emergency power supply. The closed transition contactor-based ATS is designed to meet application requirements where emergency backup power is required with no momentary loss of power by connecting both sources before the transfer occurs. Closed transition also permits periodic testing of the emergency power source without interrupting power to the loads.
Specs
Features | |
ATC-300+ microprocessor-based controller | 2 poles, 3 wires |
Voltage and frequency sensing | High withstand and closing ratings |
Multiple field programmable set points | Status display including switch position indication |
Source availability indication | Source 1 and Source 2 auxiliary contacts |
True RMS voltage and frequency sensing | Programmable plant exerciser |
System test pushbutton | Mimic diagram |
Double-throw, mechanically interlocked transfer mechanism | Switch position indication |
Status display | Double-throw UL 1008 2-position contactors |
Options | |
2 or 4-position test switch | Multi-meter options available |
Delayed Transition and Closed Transition | Selectable automatic or non-automatic operation |
Space heaters (recommended for use in NEMA 3R enclosures) | Surge suppression |
Remote communications | Load shed from emergency |
Controller availability: ATC-100, ATC-300+ and ATC-800 | Field selectable, multi ratio, control voltage transformer 50/60Hz |
Option Delayed Transition Includes | |
Time Delay Neutral | Pre-Transfer Signal with 1 N.O. and 1 N.C. contacts |
Ratings | |
Wall Mount 40-600A, 2 or 3 Pole | Floor Standing 600A 4 Pole and 800-1200A 2, 3, or 4 Pole |
Two-position contactors 40-400A | Three-position contactors 40-1200A |
Up to 600 Vac, 50/60Hz | 100% rated |
UL 1008 listed | CSA C22.2 No. 178 certified |
IBC 2006, CBC 2007 and OSHPD | |
Contact Composition | |
Caterpillar utilizes silver composition contacts designed to meet the stringent requirement of UL 1008. All contactors are designed so that the contacts can be visually inspected without major disassembly and are protected by arcing contacts. | |
Controls and Wiring | |
All control relays and industrial-grade relays are totally encapsulated to minimize exposure to dust and dirt. Lugs are 90 degrees Celsius rated and all control wire is #16 AWG, type XLPE with a 125 degrees Celsius temperature rating. | |
Enclosure | |
The ATS is housed in rugged steel NEMA 1 (for indoor) or NEMA 3R (for outdoor) enclosure, which is Seismic Zone 4 Qualified (BOCA, CBC, IBC, UBC). ATS enclosures have three door hinges to ensure proper support of the door and door mounted devices. The hinges have removable hinge pins to facilitate door removal for easy wall mounting or service and are supplied with pad-lockable latches. |
Dimensions | |||||||
Ampere Rating | Number of Poles | Height inches (mm) | Width inches (mm) | Depth inches (mm) | Load Side, Normal and Standby Source | Neutral Connection | Shipping Weight Lbs (kg) |
150-200 @120-480V | 2 | 38.68 (982.5) | 18.31(465.1) | 13.34 (338.8) | (1) #6-300 kcmil | (3) 1/0-250 kcmil | 156 (70.8) |
Product Downloads
Warranty
2 years from startup or 5 years from ship date - whichever comes first.